Aztech performed Non-Destructive Testing on concrete prior to core drilling for electrical and mechanical contractors on site. Aztech utilized Ground Penetrating Radar to locate post-tension cables and rebar in the slab prior to core drilling. Aztech scanned over 5,000 locations throughout the duration of the project. Aztech also utilized Radiographic inspection to confirm location of post-tension cables for new core locations. Throughout the project Aztech performed x-ray at over 4,000 locations. We even completed 1,200+ in under 20 days on site averaging over 60 locations per night with 1 crew.